首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   78篇
  免费   7篇
化学   76篇
晶体学   1篇
数学   1篇
物理学   7篇
  2022年   1篇
  2021年   2篇
  2020年   8篇
  2019年   9篇
  2018年   5篇
  2017年   8篇
  2016年   5篇
  2015年   3篇
  2014年   8篇
  2013年   9篇
  2012年   7篇
  2011年   8篇
  2010年   5篇
  2009年   3篇
  2008年   2篇
  2007年   1篇
  2005年   1篇
排序方式: 共有85条查询结果,搜索用时 0 毫秒
81.
A separation-preconcentration procedure was developed for the determination of trace amounts of copper, nickel, manganese and cadmium ions in water samples by flame atomic absorption spectrometry after coprecipitation by Co(OH)2 as a carrier without a chelating agent. The influence of the various analytical parameters such as pH, amount of carrier reagent, standing time, centrifugation rate and time, sample volume and matrix effects on the recovery of the analyte ions was studied. Under the specified experimental conditions the calibration curves for Ni(II) and Cu(II) were linear from 0.5 to 200 ng mL?1 and for Mn(II) and Cd(II) from 0.5 to 250 and 0.3 to 80 ng mL?1, respectively. The relative standard deviations for seven replicate determinations of a mixture of 40.0 ng mL?1 of Cu(II), Ni(II), Mn(II) and 20 ng mL?1 of Cd(II) in the original solution were 1.9%, 1.7%, 1.8% and 2.1%, respectively. The detection limits based on 3Sb/m for Cu(II), Ni(II), Mn(II) and Cd(II) in the original solution were 0.2, 0.2, 0.3 and 0.07 ng mL?1, respectively. The limits of quantification based on 10Sb/m for Cu(II), Ni(II), Mn(II) and Cd(II) in the original solution were 6.7, 6.7, 10.0 and 2.3 ng mL?1, respectively. The proposed method has been applied to the determination of trace amounts of the analyte ions in two certified reference materials (the National Institute for Environment Studies (NIES) No. 1 Pepperbush and NIES No. 7 Tea Leaves) and water samples and satisfactory results were obtained.  相似文献   
82.
Stochiometric reaction of salicylaldoxime and tantalum or niobium ethoxide in toluene at room temperature resulted in formation of [M2O(C7H5NO2)2(C2H5O)4], M=Ta and Nb which were crystallized from CH2Cl2 at −5 °C and characterized by spectroscopic techniques. The molecular structures of [Ta2O(C7H5NO2)2(C2H5O)4] was determined by single-crystal X-ray diffraction and compared with molecular structure of [Nb2O(C7H5NO2)2(C2H5O)4]. The geometries at metal atoms are distorted octahedron which shared an apex through bridged oxygen. Each dianionic salicylaldoximate ligand chelates to the one metal ion through its phenolic oxygen and oximate nitrogen atoms, and to another metal ion through its oximate oxygen atom.  相似文献   
83.
A simple synthesis of 1,2,3,5-tetrasubstituted pyrrole derivatives from the reaction of enaminone withα-haloketones,under solvent-free conditions,is described.  相似文献   
84.
A rapid and an efficient method for the preparation of a variety of substituted quinolines has been developed through the reactions of o‐aminoarylketones with carbonyl compounds containing a reactive α‐methylene moiety in the presence of molten [Et3NH][HSO4] under solvent‐free conditions in high yields. J. Heterocyclic Chem., (2011).  相似文献   
85.
1-(2-pryidylazo)-2-naphthol (PAN) immobilized on sodium dodecyl sulfate-coated nano alumina was developed for the preconcentration and determination of metal cations Co (II) from environmental and food samples. The research results displayed that adsorbent has the highest adsorption capacity for Co (II) in this system. Desorption by elution of the adsorbent with 2.0?ml of a mixture of nitric acid and ethanol was carried out. After phase separation, the enriched analyte in the final solution is determined by flame atomic absorption spectrometry (FAAS) by using a micro sample introduction system. Analytical influencing parameters including pH value, amount of sorbent, equilibrium time, sample volume, volume and concentration of eluent were examined. The effect of common matrix ions has also been investigated and it was found that they had no influence on cobalt preconcentration. Under the optimum experimental conditions, the maximum capacity of sorbent was obtained as 20?mg?g?1. The preconcentration factor and limit of detection were found to be 250 and 0.15?µg?L?1, respectively. This method showed good precision with the relative standard deviation (RSD) of 2.4% and 2.1% in concentrations of 20 and 50?µg?L?1, respectively. The accuracy of the method was evaluated by comparison of results with those obtained by electrothermal atomic absorption spectrometry. This method was successfully applied for preconcentration and determination of Co (II) in environmental and food samples.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号